DRCMR Logo 300px Color
 
Monday, 07 February 2022 11:08

CoBS 2021

held in November 2021

 Plakat COBS

We welcome international students, researchers, clinicians, and representatives from the industry to join the COPENHAGEN BRAIN STIMULATION WEEK 2021 - a course offering full immersion into transcranial brain stimulation. The course provides knowledge and know-how enabling attendees to carry out high-quality brain stimulation experiments and analyses covering all non-invasive modalities (TMS, TDCS, TACS, TUS).

The program entails four days of keynote presentations from renowned international scientists in the morning followed by hands-on sessions spanning from basic physiology and physics of brain stimulation to clinical applications in the afternoon.

The course ends with a 1-day-symposium on Friday November 5th feating talks from international experts on brain stimulation.

Registration:

To register for this course, please send an e-mail with:

  • Your name 
  • Place of employment 
  • Position
  • Dietary restrictions and
  • E-mail address

to

After registering for this event, you’ll receive further information about finalizing your registration, accommodation, public transport and more. Deadline for registration and payment is 17 October 2021.

Payment

https://drcmrworkshop.easysignup.com/5/

Address:        

DRCMR - Danish Research Centre for Magnetic Resonance
Copenhagen University Hospital Hvidovre
Kettegård Alle 30
DK-2650 Hvidovre

Date:                                   

1-5 November 2021 (Workshop)

5 November 2021 (Symposium)

Price:              

€590 (Students €390) including reading materials, light breakfast, coffee/tea & light lunches. 

Deadline:       

17 October 2021

Organizers:         

Prof. Hartwig Siebner

Prof. Axel Thielscher

Postdoc Lasse Christiansen

PhD Student Mads Alexander Just Madsen

Language:     

English

 

Selected Publications

Gregersen, F., Eroğlu, H. H., Göksu, C., Puonti, O., Zuo, Z., Thielscher, A. & Hanson, L. G.
MR imaging of the magnetic fields induced by injected currents can guide improvements of individualized head volume conductor models.
Imaging Neuroscience. 2, p. 1-15, https://doi.org/10.1162/imag_a_00176 (2024).

Göksu, C., Gregersen, F., Scheffler, K., Eroğlu, H. H., Heule, R., Siebner, H. R., Hanson, L. G. & Thielscher, A. Volumetric measurements of weak current-induced magnetic fields in the human brain at high resolution. Magn Reson Med.  DOI: 10.1002/mrm.29780 (2023).

Hosseini, S., Puonti, O., Treeby, B., Hanson, L. G. & Thielscher, A.
A Head Template for Computational Dose Modelling for Transcranial Focused Ultrasound Stimulation. NeuroImage. p. 120227. DOI: 0.1016/j.neuroimage.2023.120227 (2023).

Rahbek, S., Mahmood, F., Tomaszewski, M. R., Hanson, L. G. & Madsen, K. H. Decomposition-based framework for tumor classification and prediction of treatment response from longitudinal MRI, Phys in Med and Biol. DOI: 10.1088/1361-6560/acaa85, 2023.

Rahbek, S., Schakel, T., Mahmood, F., Madsen, K. H., Philippens, M. E. P. & Hanson, L. G. Optimized flip angle schemes for the split acquisition of fast spin-echo signals (SPLICE) sequence and application to diffusion-weighted imaging. Magn Reson Med, DOI: 10.1002/mrm.29545, 2023.

Laustsen, M., Andersen M., Xue, R., Madsen, K. H., & Hanson, L. G.Tracking of rigid head motion during MRI using an EEG system, Magn Reson Med, DOI: 10.1002/mrm.29251, 2022.

Gregersen, F., Göksu, C., Schaefers, G., Xue, R., Thielscher A., & Hanson L. G., Safety evaluation of a new setup for Transcranial Electric Stimulation during Magnetic Resonance Imaging, Brain Stimulation. 14, 3, p. 488-497, 2021.

Göksu, C., Scheffler, K., Gregersen, F., Eroğlu, H. H., Heule, R., Siebner, H. R., Hanson, L. G. & Thielscher, A. Sensitivity and resolution improvement for in vivo magnetic resonance current-density imaging of the human brain. Magn. Reson. Med. 86, p. 3131-3146, 2021.

Rahbek, S., Madsen, K. H., Lundell, H., Mahmood, F. & Hanson, L. G. Data-driven separation of MRI signal components for tissue characterization. J. Mag. Res. 333, p. 1-11. 2021.

Busoni, S., Bock, M., Chmelik, M., Colgan, N., De Bondt, T., Hanson, L. G., Israel, M., Kugel, H., Maieron, M., Mazzoni, L. N., Seimenis, I. & Vestergaard, P. ADDENDUM to EFOMP Policy statement No.14 "The role of the Medical Physicist in the management of safety within the magnetic resonance imaging environment: EFOMP recommendations". Physica Medica. 89, p. 303-305, 2021.

Sánchez-Heredia, J. D., Olin, R. B., McLean, M. A., Laustsen, C., Hansen A., Hanson, L.G., & Ardenkjaer-Larsen, J. H., Multi-Site Benchmarking of Clinical 13C RF Coils at 3 T, J Magn Reson, 318:106798, 2020.

Olin, R. B., Sánchez-Heredia, J. D., Schulte, R. F., Bøgh, N., Hansen, E. S. S., Laustsen, C., Hanson, L. G. & Ardenkjaer-Larsen, J. H. Three-dimensional accelerated acquisition for hyperpolarized 13 C MR  with blipped stack-of-spirals and conjugate-gradient  SENSE. Magn Reson Med 84, p. 519-34, 2020.

Pedersen, J. O., Hanson, C. G., Xue, R. & Hanson, L. G. Inductive measurement and encoding of k-space trajectories in MR raw data. MAGMA 32, p. 655-667, 2019.

Göksu, C., Scheffler K., Siebner H. R., Thielscher, A., & Hanson, L. G. The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI), Phys Med 59, p. 142-150, 2019.

Pedersen, J. O., Hanson, C. G., Xue, R. & Hanson, L. G. Regularization of Digitally Integrated, Inductive k-Space Trajectory Measures.
ISMRM 27th Annual Meeting & Exhibition 2019.

Pasquinelli, C., Hanson, L. G., Siebner, H. R., Lee, H. J. & Thielscher, A. Safety of transcranial focused ultrasound stimulation: A systematic review of the state of knowledge from both human and animal studies. Brain Stimulation. 12, 6, p. 1367-13802019.

Hansen, R. B., Sánchez-Heredia, J. D., Bøgh, N., Hansen, E. S. S., Laustsen C., L. G. Hanson & Ardenkjær-Larsen,  J. H. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI, Magn Reson Med 82, p. 2104-17, 2019.

Göksu, C., Scheffler K., Siebner H. R., Thielscher, A., & Hanson, L.G. The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI), Phys Med 59, 142-150, 2019.

Magnusson, P., Boer, V., Marsman, A., Paulson, O. B., Hanson, L. G. & Petersen, E. T. Gamma-aminobutyric acid edited echo-planar spectroscopic imaging (EPSI) with MEGA-sLASER at 7T, Magn Reson Med, 81(2), p. 773-780, 2019.

Pedersen, J. O. Encoding of non-MR signals in Magnetic Resonance Imaging data. PhD thesis, Technical University of Denmark, Electrical Engineering, 2018.

Pedersen, J. O., Hanson, C. G., Xue, R.  & Hanson, L. G. General Purpose Electronics for Real-Time Processing and encoding of non-MR Data in MR Acquisitions, Concepts in Magn Reson B, 48B(2), e21385, 2018.

Eldirdiri, A., Posse, S., Hanson, L. G., Hansen, R. B., Holst, P., Schøier, C., Kristensen, A. T., Johannesen, H. H., Kjaer, A., Hansen, A. E.  & Ardenkjær-Larsen, J. H. Development of a Symmetric Echo Planar Spectroscopic Imaging Framework for Hyperpolarized 13C Imaging in a Clinical PET/MR Scanner, Tomography, 4(3), p. 110-22, 20184(3), p. 110-22, 2018.

Wilhjelm J. E., Duun-Henriksen J. & Hanson L. G., A virtual scanner for teaching fundamental magnetic resonance in biomedical engineering, Comput Appl Eng Educ, 26(6), p. 2197-2209, 2018

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Human in-vivo brain magnetic resonance current density imaging (MRCDI). NeuroImage. 171, p. 26-39, 2018.

Göksu C, Scheffler K, Ehses P, Hanson L.G & Thielscher A. Sensitivity Analysis of Magnetic Field Measurements for Magnetic Resonance Electrical Impedance Tomography (MREIT), Magnetic Resonance in Medicine. 79, p. 748-760, 2018.

Laustsen, M., Andersen, M., Lehmann, P. M., Xue, R., Madsen, K. H. & Hanson, L. G. Slice-wise motion tracking during simultaneous EEG-fMRI. Joint Annual Meeting ISMRM-ESMRMB 2018.

Petersen, J. R., Pedersen, J. O., Zhurbenko, V., Ardenkjær-Larsen, J. H. & Hanson, L. G. Ultra-low power transmitter for encoding non-MR signals in Magnetic Resonance  recordings. Joint Annual Meeting ISMRM-ESMRMB 2018.

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Comparison of two alternative sequences for human in-vivo brain MR Current Density Imaging (MRCDI). Joint Annual Meeting ISMRM-ESMRMB 2018.

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Human In-vivo Brain MR Current Density Imaging (MRCDI) based on Steady-state Free Precession Free Induction Decay (SSFP-FID). Joint Annual Meeting ISMRM-ESMRMB 2018.

Andersen, M., Hanson, L. G., Madsen, K. H., Wezel, J., Boer, V., van der Velden, T., van Osch, M. J. P., Klomp, D., Webb, A. G. & Versluis, M. J. Measuring motion-induced B0 -fluctuations in the brain using field probes. Magnetic Resonance in Medicine, 75(5):2020-30, 2016.

Andersen, M., Towards Motion-Insensitive Magnetic Resonance Imaging Using Dynamic Field Measurements. PhD thesis, Technical University of Denmark, Electrical Engineering. 109 p., 2016.

Hanson, L. G. The Ups and Downs of Classical and Quantum Formulations of Magnetic Resonance. Book chapter in Anthropic Awareness: The Human Aspects of Scientific Thinking in NMR Spectroscopy and Mass Spectrometry. Edited by: C Szantay, Jr. Elsevier, Chap. 3, p. 141-171, 2015.

de Nijs, R., Miranda, MJ., Hansen, LK., Hanson, LG. Motion correction of single-voxel spectroscopy by independent component analysis applied to spectra from nonanesthetized pediatric subjects. Magn Reson Med 2009, 62(5), 1147-1154.

Hanson, LG. Is quantum mechanics necessary for understanding magnetic resonance? Concepts in Magnetic Resonance Part A 2008, 32A(5), 329-340.

Hanson, LG. A graphical simulator for teaching basic and advanced MR imaging techniques. Radiographics 2007, 27(6), e27.

Hanson, LG., Lund, TE., Hanson, CG. Encoding of electrophysiology and other signals in MR images. J. Magn Reson Imaging 2007, 25(5), 1059-1066. 

Hanson, LG., Lund, TE., Hanson, CG. Encoding and transmission of signals as RF signals for detection using an MR apparatus. WO/2005/116676, PCT/DK2005/000343 2005.

Andersen, IK., Szymkowiak, A., Rasmussen, CE., Hanson, LG., Marstrand, JR., Larsson, HB. & Hansen, LK. Perfusion quantification using Gaussian process deconvolution. Magn Reson Med 2002, 48(2), 351-361.

Hanson, LG., Adalsteinsson, E., Pfefferbaum, A., Spielman, DM. Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging. Magn Reson Med 2000, 44(1), 10-18.

Hanson, LG., Schaumburg, K., Paulson, OB. Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging. Magn Reson Med 2000, 44(3), 412-417.

News & Events

Group Members

Lars G. Hanson

Group Leader

External Collaborators

Section for MR, DTU Health Tech

Technical University of Denmark, Lyngby


Institute of Biophysics

Chinese Academy of Sciences, Beijing, China


Max Planck Institute for Biological Cybernetics

Tübingen, Germany