DRCMR Logo 300px Color
 

[EXPIRED] The Capital Region of Copenhagen is looking for a 2-years Research Assistant in transcranial stimulation-based brain circuit therapy

Are you eager to contribute to new forms of treatments for depression using personalized transcranial magnetic stimulation? Do you wish to pursue cutting-edge research at the intersection of clinical neuroscience and non-invasive brain stimulation? Then you should join us at DRCMR as we scale up our efforts to develop novel treatments for Major depressive disorder (MDD) based on brain mapping (magnetic resonance imaging [MRI] and electroencephalography [EEG]) and state-of-the-art personalized transcranial magnetic stimulation (TMS).

The position:

You will be employed as research assistant for 2 years at the Danish Research Centre for Magnetic Resonance (DRCMR). The employment period may lay the foundation for an extension into a PhD position. You will join the Brain network modulation group (https://www.drcmr.dk/brain-network-modulation) led by Prof. Hartwig Siebner and contributing to Precision brain circuit therapy (Precision-BCT) project (https://www.drcmr.dk/precision-bct), a multidisciplinary project involving Region H (Hvidovre Hospital and CNDR Psychiatric Center Glostrup), DTU Health Technology, and industrial partners.

Your role:

As our new research assistant, you will primarily be involved in carrying out an interventional study with TMS and neuro-navigated circuit stimulation, but also in other brain imaging experiments. You will have the opportunity to collaborate with an interdisciplinary team consisting of M.D.’s, psychologists, physiologists, engineers, and basic- and clinical neuroscientists.

Your daily tasks will vary according to the flow of the project, but will mainly center around:

  • Contributing to practical experimental routine, including subject recruitment, data collection, and analysis.
  • Conducting interventional brain stimulation studies in healthy volunteers and patients with MDD, involving the combination of EEG and TMS.
  • Assisting in acquiring and analyzing behavioral, and brain mapping data (e.g., EEG, fMRI) for assessing TMS efficacy.
  • Assisting in activities related to other Precision-BCT groups.
  • Engaging in teaching, knowledge dissemination, and publication of results in international, recognized scientific journals.                                                                         

Qualification Requirements

  • You hold a master’s degree in Neuroscience, Medicine, Biomedical engineering, Psychology, or related fields.
  • You enjoy being part of a multidisciplinary and international research team and integrating technological innovations into your neuroscience research.
  • You enjoy active involvement in the experimental procedures in the lab.
  • You possess strong interpersonal communication skills.
  • Experience in any of the following areas is advantageous:
    • Working with brain stimulation modalities and its integration with brain mapping methods (e.g., TMS/EEG)
    • Programming skills (preferably in Matlab or Python).
    • Processing and analyzing EEG/functional MRI data.
    • Conducting experiments with human subjects—preferably including patients.

The project will be led by Prof. Hartwig Siebner with this position under the daily supervision of Postdoc Armita Faghani.

About us:

The Danish Research Centre for Magnetic Resonance (DRCMR) is one of the leading research centers for biomedical MRI in Europe (www.drcmr.dk). Our mission is to triangulate MR physics, basic physiology, and clinical research. Approximately 75 researchers from a diverse range of disciplines are currently pursuing basic and clinical research using MR, electrophysiology, and brain stimulation to improve our understanding of the human brain and its disorders. The DRCMR is embedded in the Department of Radiology and Nuclear Medicine, a large diagnostic imaging department including all biomedical imaging modalities at Copenhagen University Hospital Hvidovre.

Selected Publications

Gregersen, F., Eroğlu, H. H., Göksu, C., Puonti, O., Zuo, Z., Thielscher, A. & Hanson, L. G.
MR imaging of the magnetic fields induced by injected currents can guide improvements of individualized head volume conductor models.
Imaging Neuroscience. 2, p. 1-15, https://doi.org/10.1162/imag_a_00176 (2024).

Göksu, C., Gregersen, F., Scheffler, K., Eroğlu, H. H., Heule, R., Siebner, H. R., Hanson, L. G. & Thielscher, A. Volumetric measurements of weak current-induced magnetic fields in the human brain at high resolution. Magn Reson Med.  DOI: 10.1002/mrm.29780 (2023).

Hosseini, S., Puonti, O., Treeby, B., Hanson, L. G. & Thielscher, A.
A Head Template for Computational Dose Modelling for Transcranial Focused Ultrasound Stimulation. NeuroImage. p. 120227. DOI: 0.1016/j.neuroimage.2023.120227 (2023).

Rahbek, S., Mahmood, F., Tomaszewski, M. R., Hanson, L. G. & Madsen, K. H. Decomposition-based framework for tumor classification and prediction of treatment response from longitudinal MRI, Phys in Med and Biol. DOI: 10.1088/1361-6560/acaa85, 2023.

Rahbek, S., Schakel, T., Mahmood, F., Madsen, K. H., Philippens, M. E. P. & Hanson, L. G. Optimized flip angle schemes for the split acquisition of fast spin-echo signals (SPLICE) sequence and application to diffusion-weighted imaging. Magn Reson Med, DOI: 10.1002/mrm.29545, 2023.

Laustsen, M., Andersen M., Xue, R., Madsen, K. H., & Hanson, L. G.Tracking of rigid head motion during MRI using an EEG system, Magn Reson Med, DOI: 10.1002/mrm.29251, 2022.

Gregersen, F., Göksu, C., Schaefers, G., Xue, R., Thielscher A., & Hanson L. G., Safety evaluation of a new setup for Transcranial Electric Stimulation during Magnetic Resonance Imaging, Brain Stimulation. 14, 3, p. 488-497, 2021.

Göksu, C., Scheffler, K., Gregersen, F., Eroğlu, H. H., Heule, R., Siebner, H. R., Hanson, L. G. & Thielscher, A. Sensitivity and resolution improvement for in vivo magnetic resonance current-density imaging of the human brain. Magn. Reson. Med. 86, p. 3131-3146, 2021.

Rahbek, S., Madsen, K. H., Lundell, H., Mahmood, F. & Hanson, L. G. Data-driven separation of MRI signal components for tissue characterization. J. Mag. Res. 333, p. 1-11. 2021.

Busoni, S., Bock, M., Chmelik, M., Colgan, N., De Bondt, T., Hanson, L. G., Israel, M., Kugel, H., Maieron, M., Mazzoni, L. N., Seimenis, I. & Vestergaard, P. ADDENDUM to EFOMP Policy statement No.14 "The role of the Medical Physicist in the management of safety within the magnetic resonance imaging environment: EFOMP recommendations". Physica Medica. 89, p. 303-305, 2021.

Sánchez-Heredia, J. D., Olin, R. B., McLean, M. A., Laustsen, C., Hansen A., Hanson, L.G., & Ardenkjaer-Larsen, J. H., Multi-Site Benchmarking of Clinical 13C RF Coils at 3 T, J Magn Reson, 318:106798, 2020.

Olin, R. B., Sánchez-Heredia, J. D., Schulte, R. F., Bøgh, N., Hansen, E. S. S., Laustsen, C., Hanson, L. G. & Ardenkjaer-Larsen, J. H. Three-dimensional accelerated acquisition for hyperpolarized 13 C MR  with blipped stack-of-spirals and conjugate-gradient  SENSE. Magn Reson Med 84, p. 519-34, 2020.

Pedersen, J. O., Hanson, C. G., Xue, R. & Hanson, L. G. Inductive measurement and encoding of k-space trajectories in MR raw data. MAGMA 32, p. 655-667, 2019.

Göksu, C., Scheffler K., Siebner H. R., Thielscher, A., & Hanson, L. G. The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI), Phys Med 59, p. 142-150, 2019.

Pedersen, J. O., Hanson, C. G., Xue, R. & Hanson, L. G. Regularization of Digitally Integrated, Inductive k-Space Trajectory Measures.
ISMRM 27th Annual Meeting & Exhibition 2019.

Pasquinelli, C., Hanson, L. G., Siebner, H. R., Lee, H. J. & Thielscher, A. Safety of transcranial focused ultrasound stimulation: A systematic review of the state of knowledge from both human and animal studies. Brain Stimulation. 12, 6, p. 1367-13802019.

Hansen, R. B., Sánchez-Heredia, J. D., Bøgh, N., Hansen, E. S. S., Laustsen C., L. G. Hanson & Ardenkjær-Larsen,  J. H. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI, Magn Reson Med 82, p. 2104-17, 2019.

Göksu, C., Scheffler K., Siebner H. R., Thielscher, A., & Hanson, L.G. The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI), Phys Med 59, 142-150, 2019.

Magnusson, P., Boer, V., Marsman, A., Paulson, O. B., Hanson, L. G. & Petersen, E. T. Gamma-aminobutyric acid edited echo-planar spectroscopic imaging (EPSI) with MEGA-sLASER at 7T, Magn Reson Med, 81(2), p. 773-780, 2019.

Pedersen, J. O. Encoding of non-MR signals in Magnetic Resonance Imaging data. PhD thesis, Technical University of Denmark, Electrical Engineering, 2018.

Pedersen, J. O., Hanson, C. G., Xue, R.  & Hanson, L. G. General Purpose Electronics for Real-Time Processing and encoding of non-MR Data in MR Acquisitions, Concepts in Magn Reson B, 48B(2), e21385, 2018.

Eldirdiri, A., Posse, S., Hanson, L. G., Hansen, R. B., Holst, P., Schøier, C., Kristensen, A. T., Johannesen, H. H., Kjaer, A., Hansen, A. E.  & Ardenkjær-Larsen, J. H. Development of a Symmetric Echo Planar Spectroscopic Imaging Framework for Hyperpolarized 13C Imaging in a Clinical PET/MR Scanner, Tomography, 4(3), p. 110-22, 20184(3), p. 110-22, 2018.

Wilhjelm J. E., Duun-Henriksen J. & Hanson L. G., A virtual scanner for teaching fundamental magnetic resonance in biomedical engineering, Comput Appl Eng Educ, 26(6), p. 2197-2209, 2018

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Human in-vivo brain magnetic resonance current density imaging (MRCDI). NeuroImage. 171, p. 26-39, 2018.

Göksu C, Scheffler K, Ehses P, Hanson L.G & Thielscher A. Sensitivity Analysis of Magnetic Field Measurements for Magnetic Resonance Electrical Impedance Tomography (MREIT), Magnetic Resonance in Medicine. 79, p. 748-760, 2018.

Laustsen, M., Andersen, M., Lehmann, P. M., Xue, R., Madsen, K. H. & Hanson, L. G. Slice-wise motion tracking during simultaneous EEG-fMRI. Joint Annual Meeting ISMRM-ESMRMB 2018.

Petersen, J. R., Pedersen, J. O., Zhurbenko, V., Ardenkjær-Larsen, J. H. & Hanson, L. G. Ultra-low power transmitter for encoding non-MR signals in Magnetic Resonance  recordings. Joint Annual Meeting ISMRM-ESMRMB 2018.

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Comparison of two alternative sequences for human in-vivo brain MR Current Density Imaging (MRCDI). Joint Annual Meeting ISMRM-ESMRMB 2018.

Göksu, C., Hanson, L. G., Siebner, H. R., Ehses, P., Scheffler, K. & Thielscher, A. Human In-vivo Brain MR Current Density Imaging (MRCDI) based on Steady-state Free Precession Free Induction Decay (SSFP-FID). Joint Annual Meeting ISMRM-ESMRMB 2018.

Andersen, M., Hanson, L. G., Madsen, K. H., Wezel, J., Boer, V., van der Velden, T., van Osch, M. J. P., Klomp, D., Webb, A. G. & Versluis, M. J. Measuring motion-induced B0 -fluctuations in the brain using field probes. Magnetic Resonance in Medicine, 75(5):2020-30, 2016.

Andersen, M., Towards Motion-Insensitive Magnetic Resonance Imaging Using Dynamic Field Measurements. PhD thesis, Technical University of Denmark, Electrical Engineering. 109 p., 2016.

Hanson, L. G. The Ups and Downs of Classical and Quantum Formulations of Magnetic Resonance. Book chapter in Anthropic Awareness: The Human Aspects of Scientific Thinking in NMR Spectroscopy and Mass Spectrometry. Edited by: C Szantay, Jr. Elsevier, Chap. 3, p. 141-171, 2015.

de Nijs, R., Miranda, MJ., Hansen, LK., Hanson, LG. Motion correction of single-voxel spectroscopy by independent component analysis applied to spectra from nonanesthetized pediatric subjects. Magn Reson Med 2009, 62(5), 1147-1154.

Hanson, LG. Is quantum mechanics necessary for understanding magnetic resonance? Concepts in Magnetic Resonance Part A 2008, 32A(5), 329-340.

Hanson, LG. A graphical simulator for teaching basic and advanced MR imaging techniques. Radiographics 2007, 27(6), e27.

Hanson, LG., Lund, TE., Hanson, CG. Encoding of electrophysiology and other signals in MR images. J. Magn Reson Imaging 2007, 25(5), 1059-1066. 

Hanson, LG., Lund, TE., Hanson, CG. Encoding and transmission of signals as RF signals for detection using an MR apparatus. WO/2005/116676, PCT/DK2005/000343 2005.

Andersen, IK., Szymkowiak, A., Rasmussen, CE., Hanson, LG., Marstrand, JR., Larsson, HB. & Hansen, LK. Perfusion quantification using Gaussian process deconvolution. Magn Reson Med 2002, 48(2), 351-361.

Hanson, LG., Adalsteinsson, E., Pfefferbaum, A., Spielman, DM. Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging. Magn Reson Med 2000, 44(1), 10-18.

Hanson, LG., Schaumburg, K., Paulson, OB. Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging. Magn Reson Med 2000, 44(3), 412-417.

News & Events

Group Members

Lars G. Hanson

Group Leader

External Collaborators

Section for MR, DTU Health Tech

Technical University of Denmark, Lyngby


Institute of Biophysics

Chinese Academy of Sciences, Beijing, China


Max Planck Institute for Biological Cybernetics

Tübingen, Germany